Submitted by admin on Wed, 05/30/2018 - 19:31

<p><p><strong>References:<br></strong><em>Avalle (2007b)<br>Avalle and Carter (2005)<br>Bouazza and Avalle (2006 a,b)</em></p><p><strong>Method Summary</strong></p><p>Ground vibrations due to IR passes are monitored to assess its influence on nearby building structures. This test is performed by monitoring surface wave velocities at various distances away from the impact source to compare with local specifications on what is acceptable.</p><p><em> </em><strong>Accuracy and Precision</strong></p><p>Information regarding accuracy and precision of this test method was not discussed in the references cited above.</p><p><em> </em><strong>Adequacy of Coverage</strong></p><p>The coverage depends on how many sensors are used to detect the ground vibrations.</p><p><strong>Implementation Requirements </strong></p><p>Implementation of the technology requires specialized equipment and trained personnel.</p><p><em> </em><strong>General Comments</strong></p><p>The test method is used only as a QC measure to help mitigate disturbance to nearby structures. It does not provide any measurement to assess the compacted soil.</p></p>